HMK-N-T Integrated Cooling Tower SeriesIntegrated All-in-One Unit
A highly integrated cooling tower series for all-in-one system support, compact and container-shippable.
The HMK-N-T integrated series is a highly integrated cooling tower product designed by LANXUN for all-in-one system support. The cooling tower, water pump, control cabinet, and other core components are all integrated into a single frame unit, assembled and commissioned before leaving the factory. On site, only water and power connections are needed for operation. Its compact structure is sized for standard 40-foot container transport, developed specifically for data-center all-in-one units, modular equipment rooms, and containerized cooling systems. It carries LANXUN nine core technologies, including intelligent variable-frequency control, adaptive variable-flow spraying, and wireless remote monitoring, enabling one-touch startup and unattended operation.
Key Highlights
All-in-One System Support
Cooling tower + water pump + control cabinet fully integrated, ready-made from the factory and plug-and-play on site, cutting the installation period by 80%.
Nine Core Technologies
Equipped with nine technologies including intelligent variable frequency, variable-flow spraying, wireless monitoring, and automatic blowdown for intelligent unattended operation.
Container-Shipping Friendly
Standard dimensions fit 40-foot containers, convenient for sea-land combined transport, suitable for export and long-distance logistics.
High-Density Integration
At the same cooling capacity, the footprint is only 50% of a conventional solution, ideal for containerized data centers and mobile base stations.
Working Principle and Structural Features
The following content is excerpted from the HMK-N-T Integrated Cooling Tower Series product manual
Working Principle
The HMK-N-PB-T integrated unit series is a CTI cooling tower covering 15 models with circulating water volumes of 90~600m³/h. The complete unit uses modular bolted assembly: the bottom frame, side panels, cross members, tension braces, fill, distribution basin, fan stack, and power system are all assembled with bolts, giving a clear installation procedure and stable assembly quality.
Design conditions: inlet water temperature 37℃, outlet water temperature 32℃, wet-bulb temperature 28℃, dry-bulb temperature 31.5℃, atmospheric pressure 9.94×10⁴Pa, wind pressure design <47m/s. The product is certified to the US CTI standard STD-201(21) for thermal performance and holds national water-saving and energy-saving CQC product certifications.
The integrated unit series shares LANXUN's nine core technologies: full-performance compliance with the national standard GB/T 7190.1-2018, positive/negative-pressure fill molding technology with a 20-year service life (nuclear-grade quality), LAXUN 48.6dB(A) ultra-quiet, high-twist FRP fan technology, and stainless steel processing based on laser flying processing equipment.
Modular Bolted Assembly
The bottom frame, side panels, cross members, tension braces, fill, distribution basin, and more are all fastened and assembled with bolts, with no on-site welding, making installation simple and quality stable.
Hanging Fill Fixing
The fill sheets are threaded onto the film tubes for fixing and locked with screws through the film-tube end plates, making assembly and disassembly simple and cleaning and replacement easy.
Distribution Basin Water Distribution System
The nozzles are clipped onto the distribution basin, which is fixed to the side panels with distribution-basin riser plates on both sides, forming a stable gravity water distribution system.
Dual Makeup Water System
A manual makeup section and an automatic makeup section (float valve) are installed on the bottom frame to automatically maintain the water level and suit different operating conditions.
Top-Mounted Power System
The motor support frame, motor frame, motor, and fan are installed at the tower-top fan stack, with an access door, access-door ladder, and external access ladder for simple maintenance.
Technical Specifications
| Model (HMK-xxx-PB-T) | Cooling Water Flow (m³/h) | Fan Power (kW) | Pump Power (kW) | Dimensions L×W×H (mm) | Operating Weight (kg) | Noise dB(A) |
|---|---|---|---|---|---|---|
| HMK-90N-PB-T | 90 | 4.0 | 3.0 | 2800×2200×2600 | 2600 | 50.5 |
| HMK-110N-PB-T | 110 | 5.5 | 3.0 | 3000×2400×2700 | 2900 | 51.0 |
| HMK-130N-PB-T | 130 | 5.5 | 4.0 | 3200×2600×2800 | 3200 | 51.5 |
| HMK-150N-PB-T | 150 | 7.5 | 4.0 | 3400×2800×2900 | 3600 | 52.0 |
| HMK-180N-PB-T | 180 | 7.5 | 5.5 | 3600×3000×3000 | 4000 | 52.5 |
| HMK-210N-PB-T | 210 | 11.0 | 5.5 | 3800×3200×3100 | 4400 | 53.0 |
| HMK-240N-PB-T | 240 | 11.0 | 7.5 | 4000×3400×3200 | 4900 | 53.5 |
| HMK-280N-PB-T | 280 | 15.0 | 7.5 | 4200×3600×3300 | 5400 | 54.0 |
| HMK-320N-PB-T | 320 | 15.0 | 7.5 | 4400×3800×3400 | 5900 | 54.5 |
| HMK-360N-PB-T | 360 | 18.5 | 11.0 | 4600×4000×3500 | 6500 | 55.0 |
| HMK-400N-PB-T | 400 | 18.5 | 11.0 | 4800×4200×3700 | 7100 | 55.5 |
| HMK-450N-PB-T | 450 | 22.0 | 11.0 | 5000×4400×3800 | 7700 | 56.0 |
| HMK-500N-PB-T | 500 | 22.0 | 15.0 | 5200×4600×4000 | 8400 | 56.5 |
| HMK-550N-PB-T | 550 | 30.0 | 15.0 | 5400×4800×4100 | 9000 | 57.0 |
| HMK-600N-PB-T | 600 | 30.0 | 15.0 | 5600×5000×4300 | 9700 | 57.5 |
Product Gallery
Images are from the HMK-N-T Integrated Cooling Tower Series product manual



Applications
Certifications & Endorsements
Get a Detailed Technical Solution
The LANXUN technical team provides one-on-one selection support and complete specification documents. Please leave your contact details and we will reply within 24 hours.
Contact Us Now