Data Center Cooling Towers_ Indirect Evaporative Cooling_ High-efficiency Plant Cooling Towers_ Data Center Energy Saving-LANXUN Cooling Towers
Technology Zone · Data Center Cooling Solutions

Data Center Cooling Solutions

Full-path cooling solutions, efficiently matched from cold source to terminal

Full-path Cooling Solutions

In response to the growing computing density and heat dissipation demands of data centers, LANXUN provides full-path cooling solutions efficiently matched from cold source to terminal. These cover indirect evaporative cooling (IE), isenthalpic adiabatic cooling (LAD), high-efficiency plants (PL), closed circuit tower direct cooling (LMB/LXWD), and combined cooling integrating multiple technologies, comprehensively lowering the PUE of data centers and supporting green, low-carbon operations.

LANXUN data center cooling equipment installed on a rooftop

LANXUN adiabatic/dry cooler at a data center project

Six Cooling Paths

From cold source to terminal, six paths flexibly cover the needs of different scenarios

01

Full-refrigerant Cooling

Using refrigerant as the medium, achieving high-efficiency cooling through phase-change heat exchange — suitable for high-density heat load scenarios.

02

Indirect Evaporative Cooling (IE)

Indirect heat exchange between wet and dry channels lowers the supply air temperature while maintaining cleanliness.

03

Isenthalpic Adiabatic Cooling (LAD)

An adiabatic pre-cooling section lowers the intake dry-bulb temperature by 5~15℃, greatly improving cooling efficiency with energy consumption only 10%~30% of conventional systems.

04

High-efficiency Plant (PL)

Cooling towers dedicated to high-efficiency plants, combined with variable-frequency chillers and intelligent control, deliver industry-leading system energy efficiency.

05

Closed Circuit Tower Direct Cooling (LMB/LXWD)

The closed circuit avoids water quality contamination, while combined dry-wet operation achieves both year-round high-efficiency cooling and water saving.

06

Combined Cooling (PL-IE+LAD)

A combined cooling solution integrating multiple technologies, delivering ultimate energy savings and flexible adaptation.

Industry Cases

We have served multiple national-level supercomputing centers and large data centers in China

01
National Supercomputing Center Tianjin
02
National Supercomputing Center Jinan
03
National Supercomputing Center Wuxi
04
China Railway Main Data Center
05
China Mobile Data Center
06
China Telecom Data Center
07
China Unicom Data Center
08
Baidu Nansha Cloud Project
09
Zhengzhou AI Computing Center

Technology Advantage Data

Data that validates the outstanding performance of LANXUN cooling technology

0.025kW·h/m³
Power consumption ratio
Well below the national standard limit of 0.035
0.000063%
Drift loss rate
Near-zero drift loss — water-saving and environmentally friendly
5~15℃
Dry-bulb reduction
Effect of isenthalpic adiabatic pre-cooling
10~30%
Energy consumption ratio
Only a fraction of conventional air conditioning energy consumption

Get a Customized Data Center Cooling Solution

Our technical team is ready to provide professional solution consulting and selection advice